The Morelli Light Stainless Steel .022″ MBT Brackets — Single Patient Kit is a complete 20-bracket set for one full case of fixed orthodontic treatment in the MBT prescription, supplied as Light Prescription MBT with hooks on canines and premolars. Every bracket in the kit carries its own built-in torque, angulation and body length, so each tooth position is prescribed rather than adjusted at the chair.
Key Features
MBT prescription values built in — higher labial root torque on the upper incisors (+17° central, +10° lateral) and 0° torque with +8° angulation on the canines
Integrated hooks on canines and premolars — ready for elastics, retraction and auxiliary mechanics without crimping extra hardware onto the archwire
Light line body — Morelli’s Light metal bracket line, with the body length specified per tooth position (2,3 mm to 3,2 mm)
Stainless steel construction — corrosion resistance and dimensional stability throughout treatment
Low-friction slot with rounded ends — smoother wire sliding and less irritation to soft tissue
Sandblasted base with anatomical curvature — mechanical retention for the adhesive and close adaptation to the enamel surface
Technical Specifications
Material: Stainless Steel
Line: Light
Prescription: MBT
Slot: .022″ × .028″ (0,56 × 0,71 mm)
Hooks: Canines and premolars
Arch Coverage: Upper and lower, teeth 15–25 and 35–45
Quantity: 1 patient kit — 20 brackets
Purpose: Fixed orthodontic treatment with MBT prescription brackets for a single patient case
Certifications: FDA Approved, CE Approved, ISO 9001:2015, ISO 13485:2016
Country of Manufacture: Brazil
Package Includes: 1 patient kit with 20 Light MBT brackets (10 upper, 10 lower), slot .022″, with hooks on canines and premolars
Torque and Angulation
Upper central incisor (11/21): torque +17° · angulation +4° · length 3,2 mm
Upper lateral incisor (12/22): torque +10° · angulation +8° · length 2,5 mm
Upper canine (13/23): torque 0° · angulation +8° · length 2,7 mm
Upper first premolar (14/24): torque -7° · angulation 0° · length 2,9 mm
Upper second premolar (15/25): torque -7° · angulation 0° · length 2,9 mm
Lower central incisor (31/41): torque -6° · angulation 0° · length 2,3 mm
Lower lateral incisor (32/42): torque -6° · angulation 0° · length 2,3 mm
Lower canine (33/43): torque 0° · angulation +3° · length 2,7 mm
Lower first premolar (34/44): torque -12° · angulation +2° · length 2,9 mm
Lower second premolar (35/45): torque -17° · angulation +2° · length 2,9 mm
Clinical Applications
Fixed orthodontic treatment in the MBT prescription, from initial alignment through finishing
Sliding mechanics and space closure, using the integrated canine and premolar hooks as elastic anchorage
Case-by-case bonding when a single full-arch set is needed without holding bulk stock
Why prescribe at the bracket?
Every bracket carries its own torque, angulation and body length. The upper central incisor is built at +17° torque and the upper canine 0° torque with +8° angulation, so the prescription sits in the bracket body rather than being bent into the wire.